Comparison of energy use efficiency of greenhouse and indoor plant factory system

Ying Zhang and M. Kacira
Department of Biosystems Engineering, The University of Arizona, Tucson, USA

SUMMARY
Energy use efficiency in greenhouse and indoor plant factory system is greatly affected by outdoor climates, structure properties, operating conditions and product types. Energy use efficiency for two greenhouse cases and two indoor plant factory cases were compared in simulation with annual lettuce biomass yield and energy consumption including lighting, heating, and cooling for six geographic locations with different climates (Duluth, Minnesota; Seattle, Washington; Phoenix, Arizona; Miami, Florida; Abu Dhabi, UAE; and Riyadh, KSA). The energy balance of a greenhouse was simulated including Greenhouse 1 (GH_1) with a shading curtain (50% shade percentage) deployed during high radiation seasons and Greenhouse 2 (GH_2) with a constant daily light integral level (DLI) of 15 mol m-2 d-1 achieved by supplemental lights and variable shading controls. In indoor plant factory model, two cases Indoor Plant Factory 1 (IPF_1) and Indoor Plant Factory 2 (IPF_2) were simulated with EnergyPlus, a building simulation program, with the DLIs of 13 mol m-2 d-1 and 15 mol m-2 d-1 respectively. Using LED lights with high efficacy (2.5 µmol J-1), indoor plant factories were determined to be superior to greenhouses in cold climates with energy use efficiency as high as 0.13 kg kWh-1 and 0.14 kg kWh-1 respectively in Duluth and Seattle compared to greenhouse cases with 0.10 kg kWh-1 and 0.11 kg kWh-1 respectively. In hot climates greenhouses are significantly more efficient than indoor plant factories, with the highest energy use efficiency of 0.35 kg kWh-1 in Miami. Parameters of indoor plant factory systems, including heating, ventilation, and air conditioning (HVAC) economizers, the number of tiers of production shelves, lettuce plant transpiration rate, and light efficacy, were evaluated for their impacts on energy usage and effectiveness for energy savings. Choosing LED lights with high efficacy was recommended to effectively reduce the electricity usage and to enhance energy use efficiency for indoor plant factories.

Keywords economizer, energy consumption, HVAC system, lettuce, light efficacy, transpiration

Significance of this study

What is already known on this subject?

  • Energy consumption in indoor plant factory system is significant. The energy use efficiency in greenhouse and indoor plant factory system are greatly affected by outdoor climates, structure properties, operating conditions and types of crop growing inside. It is important to assess the differences of energy use efficiency in these two systems and explore potential energy-saving strategies.
What are the new findings?
  • The energy use efficiency of indoor plant factory system can be comparable to greenhouse system when operating in cold climate. However, in hot climate, greenhouses are significantly more efficient than indoor plant factories in terms of energy consumption. Plant transpiration and heat loads from sole source lighting system greatly affects the cooling loads and heating loads of HVAC system in indoor plant factory.
What is the expected impact on horticulture?
  • Energy use efficiency for various greenhouses and indoor plant factory system types, parametric evaluations for six climates are reported. Integrating HVAC economizer and choosing high efficiency of LED lights are recommended to enhance energy use efficiency in indoor plant factory system.

Download fulltext version How to cite this article       Export citation to RIS format      

E-mail: mkacira@arizona.edu  

References

  • Both, A. (2003). Ten years of hydroponic lettuce research. https://www.researchgate.net/publication/266453402_TEN_YEARS_OF_HYDROPONIC_LETTUCE_RESEARCH.

  • Boulard, T., and Wang, S. (2002). Experimental and numerical studies on the heterogeneity of crop transpiration in a plastic tunnel. Comput. Electron. Agric. 34, 173–190. https://doi.org/10.1016/S0168-1699(01)00186-7.

  • Defraeye, T., Verboven, P., Ho, Q.T., and Nicolai, B. (2013). Convective heat and mass exchange predictions at leaf surfaces: Applications, methods and perspectives. Comput. Electron. Agric. 96, 180–201. https://doi.org/10.1016/j.compag.2013.05.008.

  • Eaves, J., and Eaves, S. (2018). Comparing the profitability of a greenhouse to a vertical farm in Quebec. Can. J. Agric. Econ. 66, 43–54. https://doi.org/10.1111/cjag.12161.

  • Graamans, L., Baeza, E., Van den Dobbelsteen, A., et al. (2018). Plant factories versus greenhouses: Comparison of resource use efficiency. Agric. Syst. 160, 31–43. https://doi.org/10.1016/j.agsy.2017.11.003.

  • Graamans, L., Van den Dobbelsteen, A., Meinen, E., and Stanghellini, C. (2017). Plant factories; crop transpiration and energy balance. Agric. Syst. 153, 138–147. https://doi.org/10.1016/j.agsy.2017.01.003.

  • Gupta, S.K., Ram, J., and Singh, H. (2018). Comparative study of transpiration in cooling effect of tree species in the atmosphere. J. Geosci. Environm. Prot. 6, 151–166. https://doi.org/10.4236/gep.2018.68011.

  • Harbick, K., and Albright, L.D. (2016). Comparison of energy consumption: Greenhouses and plant factories. Acta Hortic. 1134, 285–292. https://doi.org/10.17660/ActaHortic.2016.1134.38.

  • Hosni, M.H., Jones, B.W., and Xu, H. (1999). Experimental results for heat gain and radiant/convective split from equipment in buildings.

  • Kacira, M., Jensen, M., Robie, T., Tollefson, S., and Giacomelli, G. (2017). Use resources wisely: Waste management and organic liquid fertilizer use in greenhouse production system. Acta Hortic. 1164, 541–548. https://doi.org/10.17660/ActaHortic.2017.1164.71.

  • Kalantari, F., Tahir, O.M., Joni, R.A., and Fatemi, E. (2018). Opportunities and challenges in sustainability of vertical farming: A review. J. Landsc. Ecol. Rep. 11, 35–60. https://doi.org/10.1515/jlecol-2017-0016.

  • Lee, K.P., and Chen, H.L. (2013). Analysis of energy saving potential of air-side free cooling for data centers in worldwide climate zones. Energy Build. 64, 103–112. https://doi.org/10.1016/j.enbuild.2013.04.013.

  • Liu, R., Zhou, X., Lochhead, S.J., et al. (2017). Low-energy LED lighting heat gain distribution in buildings, part II: LED luminaire selection and test results. Sci. Technol. Built. Environm. 23, 688–708. https://doi.org/10.1080/23744731.2016.1250563.

  • Marsh, L.S. (1987). A model of greenhouse hydroponic lettuce production: Daily selection of optimum air temperatures and comparison of greenhouse covers. Cornell University.

  • Mesmoudi, K., Soudani, A., and Bournet, P. (2010). Determination of the inside air temperature of a greenhouse with tomato crop under hot and arid climates. J. Appl. Sci. Environm. Sanit. 5, 117–129.

  • Morgan Pattison, P., Hansen, M., and Tsao, J.Y. (2018). LED lighting efficacy: Status and directions. Comptes Rendus Phys. 19, 134–145. https://doi.org/10.1016/j.crhy.2017.10.013.

  • Okada, K., Yehia, I., Teitel, M., and Kacira, M. (2018). Crop production and energy generation in a greenhouse integrated with semi-transparent organic photovoltaic film. Acta Hortic. 1227, 231–239. https://doi.org/10.17660/ActaHortic.2018.1227.28.

  • Pearson, S., Wheeler, T.R., Hadley, P., and Wheldon, A.E. (1997). A validated model to predict the effects of environment on the growth of lettuce (Lactuca sativa L.): Implications for climate change. J. Hortic. Sci. 72(4), 503–517. https://doi.org/10.1080/14620316.1997.11515538.

  • Pollet, S., Bleyaert, P., and Lemeur, R. (2000). Application of the Penman-Monteith model to calculate the evapotranspiration of head lettuce (Lactuca sativa L. var. capitata) in glasshouse conditions. Acta Hortic. 519, 151–161. https://doi.org/10.17660/actahortic.2000.519.15.

  • Salisbury, F.B., and Ross, C.W. (1985). Plant Physiology (Wadsworth Publishing Company).

  • Sanford, S. (2009). Reducing Greenhouse Energy Consumption – An Overview (A3907-01), p. 1–16.

  • Shimizu, H., Kushida, M., and Fujinuma, W. (2008). A growth model for leaf lettuce under greenhouse environments. Environm. Control Biol. 46, 211–219. https://doi.org/10.2525/ecb.46.211.

  • Van Henten, E.J. (1994). Validation of a dynamic lettuce growth model for greenhouse climate control. Agric. Syst. 45, 55–72. https://doi.org/10.1016/S0308-521X(94)90280-1.

  • Wang, S.K. (2001). Handbook of Air Conditioning and Refrigeration, 2nd edn. (New York, USA: McGraw-Hill Comp., Inc.).

  • Wurr, D.C.E., Fellows, J.R., and Hambidge, A.J. (1992). Environmental factors influencing head density and diameter of crisp lettuce cv. Saladin. J. Hortic. Sci. 67, 395–401. https://doi.org/10.1080/00221589.1992.11516264.

Received: 12 April 2020 | Accepted: 24 June 2020 | Published: 21 October 2020 | Available online: 21 October 2020