Vol. 53
Title: Common Faults in Mist Propagation System Design and Operation
Author: Iain G. Thorne
pp: 232-235
Abstract:
INTRODUCTION
Since 1936, when G.E.L. Spencer first set out the basic concept of mist propagation (MacDonald, 1986; Welch, 1970), most professional propagators have had some grasp of the principles involved. However, in this author's opinion they often manage to turn an essentially simple concept into a technical and commercial headache.
Mist systems are too often poorly designed and operated. The commonest examples of this are:
- Inadequate water-pressure, giving poor atomisation of water droplets.
- Mist-lines and nozzles spaced incorrectly.
- Nozzles too close to protective structures, thus inhibiting the diffusion of mist across the propagation area.
- Drips from nozzles and air in pipe work.
- Poor maintenance routines.
Too dry an atmosphere and too much water in the rooting medium make the management of a mist unit unnecessarily difficult. The two problems are often linked.
Great attention should be paid to the chemical properties of the water used. Welch set out his views and
Full text:
IPPS members
ISHS members & pay-per-view
(PDF 140329 bytes)
Translate:
IPPS membership administration
ISHS membership administration
|