Vol. 39
Title: PROPAGATING AND COOLING WITH FOG
Author: Doug Torn
pp: 390-391
Abstract:
In April, 1988 Buds & Blooms Nursery purchased a fogging machine. Our decision was based on the fact that we had begun producing our own tissue-cultured rhododendron and mountain laurel plants. We could not get satisfactory results using mist and tents in our climate.
At the nursery we have eleven double-poly propagation houses that are 14 × 96 ft. They are all vented using a W. W. Grainger 24-in. exhaust fan and a 37 × 63 in. Acme intake shutter. Both of these units are controlled by a thermostat set at 80 to 85°F. We use two layers of 40% white shade cloth over these houses when propagating. This is available from V-J Growers Supply. In the winter these houses are heated with Modine gas-fired heaters.
Two of the eleven propagation houses are used as a fog-houses for tissue-cultured plantlets. In these greenhouses we use ½ in. copper tubing suspended from the center purlin which is approximately 7 ft. from the floor. We used eight nozzles in the first house, spaced 10 ft. apart. The