Abstract:
In September, 1985, an existing glasshouse was converted into a mist propagation unit at Midland Nurseries. After looking at several systems of base heating, we opted for a hot water system, which we would design and install ourselves.
The system. At the heart of the system is an ordinary, domestic 100,000 BTU boiler, fired by liquid petroleum gas. The warm water is heated to about 30°C, and pumped along a flow header. This then feeds a flow sub-header, which feeds four 20mm alkathene pipes, which run the length of the bed. These four pipes turn at the end of the bed, to become four returns. These flow and return pipes alternate in the bed, to give even heat distribution. The warm water from the return alkathene pipes flows into a return sub-header, and from there into the return header, and back into the boiler.
The construction. The flow and return pipes are in copper for the first two metres to and from the boiler, but then change to 50mm P.V.C. pipe. The temperature in these plastic