Vol. 33
Title: EVALUATION OF COMMERCIAL MIST CONTROL UNITS
Author: R.J. Worrall
pp: 176-181
Abstract:
The performance of five commercially available mist propagation controllers were evaluated. Those tested were a cyclic timer with day/night switching, paper sensor (A.C. resistance), light sensor, resin block (capacitance) and relative humidity (temperature differential).
When properly adjusted and maintained all the units provided a constant moisture film over the test plants. There was no significant difference in rooting among plants on beds controlled by the various units. The most obvious difference among the units was the level of maintenance and the re-adjusting of required settings. Once installed and calibrated the light sensor and the relative humidity controllers required no further attention for the duration of the trial (6 weeks).