Abstract:
With the current interest in energy conservation, the efficiency of greenhouses has come under close scrutiny. The use of double walls, ground insulation, tight doors and vents is now common practice. Several new ideas are being put to use and it seems certain that energy costs can be reduced even more. I'd like to review four areas that show great promise:

Placement and Design. A complete turnabout in thinking has occurred in the orientation and construction of greenhouses. It has been found that for maximum solar energy entry, the single-span building should be positioned in an east-west direction. The north wall should be opaque, well-insulated and at an angle of about 60°. The south wall or roof performs best if built at an angle of 35° to 45° (1).

Heat Delivery. Space heating may soon be replaced by bench or floor heating. Don Dillon's Four Winds Nursery in Fremont, California, is one of many that have had success with the use of the hot water circulated inside the bench. Whitcomb