Several research projects conducted at the University of California Agricultural Experiment Station at Riverside required greenhouse facilities which have reasonably narrow temperature controls and air purification systems for protecting plants against smog damage. This report describes the application of some innovative equipment, both old and new, which have not been generally used in greenhouse facilities but which appear to be superior to "standard" greenhouse components.

Greenhouse Cooling. Cooling is essential at Riverside where summer dry bulb temperatures exceed 100°F several days per year. The standard evaporative cooling system available from greenhouse manufacturers utilize vertical excelsior pads and exhaust fans. Disadvantages of the vertical (upright) pad systems are:

  1. After a few months use, voids develop in the pads which allow uncooled air to move into the greenhouse, thereby reducing the cooling efficiency of the system.
  2. To maintain reasonable efficiency, pads must be changed