Volume 36 Number 3 Article 3 Pages: 80-83
Year 1982 Month 7
Title: Annual Chill Unit Accumulation in the U.S.
Authors: H.J. Swartz and S.E. Gray
Citation
Abstract:
The effectiveness of different temperatures in overcoming the winter
time physiologic state of dormancy
(rest) of temperate zone fruit plants
has been described (2, 3, 6). Through
controlled refrigeration experiments,
temperatures between 3°C and 10°C
were determined to be the most chill
efficient, temperatures above 15°C reversed the chilling process, and freezing or near freezing temperatures were
ineffectual.
The term, chill unit, expresses this time-effective temperature
relationship and is defined as: 1 hour
× a coefficient of the chilling efficiency of the mean hourly temperature.
The optimum temperature has
a coefficient of 1.0, ineffective temperatures have a zero coefficient, chill
reversing temperatures have a —1.0
coefficient and intermediate temperatures are assigned intermediate, fractional, coefficients.
Subsequently, the
rest requirement of many deciduous
fruit species were defined in terms of
chilling units (4, 5).